F-80
Current Probe
The model F-80
is ideal for measurements from 1 kHz to 100 MHz on large pipes, bundles
of cables, or architectural conductive structures. The aperture is 127
mm. The transfer impedance is 5W (± 3dB) from 500 kHz to 100 MHz. It can be used without saturating
up to 350 amperes of DC to 400 Hz, 100 amperes of CW or pulse current.
By adding an external power absorbing terminator to the output the model
number becomes F-80-1 with a typical transfer impedance of 1W (± 2dB) from 100 kHz to 100 MHz. It can operate without saturation
from up to 350 amperes of DC to 400 Hz, 2 amperes of CW current, and 100
amperes of pulse current. |